Orifice Size/Altitude Adjustment

For altitudes above 2,000 feet (In Canada 4,500 FT/1370

M),the orifice should be de-rated by 4% for every 1,000 feet

to maintain the proper ratio of gas to air. Improper orifice

sizing may result in damage and unsafe conditions. Chang-

ing the orifice should only be done by a qualified service

technician. Contact your Lennox Hearth Products dealer for

proper orifice sizes. (see Page 26 for more information).

Smoke Detectors

Since there are always several potential sources of fire in

any home, we recommend installing smoke detectors. If

possible, install the smoke detector in a hallway adjacent

to the room (to reduce the possibility of occasional false

activation from the heat produced by the appliance). If your

local code requires a smoke detector be installed within

the same room, you must follow the requirements of your

local code. Check with your local building department for

requirements in your area.

Codes and Approvals

Certification

Gas appliances must be tested and certified by a nation-

ally recognized testing and certification laboratory to ANSI

(American National Standard Institute) gas appliance safety

standards.

This stove has been tested and certified by OMNI -Test

Laboratories to ANSI Z21.88 / CSA 2.33 Standard for Vented

Gas Fireplace Heater and CGA 2.17-M91 and UL 307B Gas

Burning Heating Appliances for Manufactured (Mobile)

Homes in both USA and Canada.

It has met all necessary ANSI Standards and is fully certified

for installation in any community. If there are any questions

or if you need further substantiation either write to or call

your Lennox Hearth Products dealer. If you have further

questions, please contact Lennox Hearth Products.

Check all local building and safety codes before installation.

The installation instructions and appropriate code require-

ments must be followed exactly and without compromise.

In the absence of local codes the following standards and

codes must be followed.

The Epic™ Stove

• Must conform with all local, state and national installation

codes. In the absence of local codes, the installation must

conform with National Fuel Gas Code ANSI Z223.1 - latest

edition, also known as NFPA 54 (In Canada, the current

CAN/CSA B149.1 installation code). Refer to the National

Fuel Gas Code and local zoning and code authorities for

details on installation requirements.

• Mobile home installations must conform with the Mobile

Home Construction and Safety Standard, Title 24 CFR,

Part 3280 (in Canada CAN/CSA Z240 MH), or, when such a

standard is not applicable, the Standard for Mobile Home

Installations, ANSI A225.1 - latest edition.

• Must be vented directly to the outside in accordance with

the latest edition of the National Fuel Gas Code and must

never be attached to a chimney serving a separate solid

fuel burning appliance.

• Has been certified for use with either natural gas or pro-

pane.

• Is not for use with solid fuels.

• Is approved for sitting rooms and/or bedrooms.

Remove date for listing standards (was ANSI Z21.88-2005/CSA 2.33-2005) (done 2-12-08)