Section 2

Hardware Installation

10

Note:

If video quality

deteriorates you can add

a VGA amplifier between

the fifth and the sixth

KVM switch to enhance

the VGA signal. (see

www.lindy.com

for

appropriate products)

2.4 Cascading / Daisy Chaining of multiple KVM Switches

The P16-IP can be cascaded with LINDY P-Series CPU switches only. It should not be used

with LINDY PXT-Series CPU Switches. For all cascaded installations, the P16-IP should always

be used as the MASTER switch.

To connect an additional switch to the MASTER (or previous) switch, you must use a standard

(VGA + 2 x PS/2) 3-in-1 KVM cable, all connectors male.

Step 1 - Connect the local console

Connect your keyboard, mouse and monitor to the console ports of the P16-IP MASTER KVM

Switch.

Step 2

Use one end of a 3-in-1 KVM cable to connect the

daisy chain port

of the MASTER/previous

KVM Switch and the other end to the

console port

of the next SLAVE switch.

Step 3 - Cascading

Repeat the previous step to daisy chain mores switches. Each individual switch in the chain

represents a different

Bank.

The MASTER switch is Bank 1 and each cascaded SLAVE follows

on as Bank 2, 3, 4 etc. to a maximum of eight banks/switches.




Step 4 – Resetting the Switches

After you have connected and switched on the SLAVE switches and computers, all of the KVM

switches must be reset. First, reset the SLAVE switch at the end of the daisy chain and then

reset all of the other SLAVE switches up to the MASTER P16-IP switch.

To reset the switch, press and hold the Bank button and P8 button on the front panel of the

switch.

Each SLAVE switch should now show a dash in its BANK display.

Now, reset the MASTER switch - it will show a 1 in the BANK display. Each SLAVE switch

BANK display will now change to a number according to its position in the daisy chain.

Bank 1 (Master)

Bank 3...to a maximum of 8

Cascading KVM Switches