Section 4

IP Access Configuration & Operation

49

Manually

Allows adjustment of both compression rate and colour depth individually. Depending on the

selected compression rate the data stream between the P16-IP and the Remote Console will be

compressed in order to save bandwidth. Since high compression rates are very time

consuming, they should not be used when several users are accessing the P16-IP

simultaneously.

The standard colour depth is 16 bit (65536 colours). The other colour depths are intended for

slower network connections in order to allow a faster transmission of data. Therefore

compression level 0 (no compression) uses only 16 bit colour depth. At lower bandwidths only 4

bit (16 colours) and 2 bit (4 grey scales) are recommended for typical desktop interfaces. Photo-

like pictures have best results with 4 bit (16 grey scales). 1 Bit colour depth (black/white) should

only be used for extremely slow network connections.

Remote Console Type

Specifies, which Remote Console Viewer to use.

Default Java-VM

Uses the default Java Virtual Machine of your Browser. This may be the Microsoft JVM for

Internet Explorer or the Sun JVM if it is configured this way. Use of the Sun JVM may also be

forced (see below).