Modem Init String

The initialization string used by the P16-IP to initialize the modem. The default value will

work with all modern standard modems directly connected to a telephone line. In case you

have a special modem or the modem is connected to a local telephone switch that requires

a special dial sequence in order to establish a connection to the public telephone network,

you can change this setting by entering a new string. Refer to your modem’s manual about

the AT command syntax.

Modem server IP address

This IP address will be assigned to the P16-IP during the PPP handshake. Since it is a

point-to-point IP connection virtually every IP address is possible but you must make sure, it

is not interfering with the IP settings of the P16-IP and your console computer. The default

value will work in most cases.

Modem client IP address

This IP address will be assigned to your console computer during the PPP handshake.

Since it is a point-to-point IP connection virtually every IP address is possible but you must

make sure, it is not interfering with the IP settings of the P16-IP switch and your console

computer. The default value will work in most cases.

Passthrough access to serial port via Telnet

Using this option, it is possible to connect an arbitrary device to the serial port and access it

(assuming it provides terminal support) via Telnet. Select the appropriate options for the serial

port and use the Telnet Console, or a standard Telnet client to connect to the P16-IP.