Installing your ups – Panamax BANKS WIRING MB1000 User Manual

Page 4

Advertising
background image

2

HARDWARE INSTALLATION GUIDE

1. Your new UPS may be used immediately upon receipt.

However, recharging the battery for at least four hours is recom-

mended to insure that the battery’s maximum charge capacity is

achieved. Charge loss may occur during shipping and storage.

To recharge the battery, simply leave the unit plugged into an

AC outlet. The unit will charge in both the ON as well as the OFF

position. If you wish to use the software, connect the enclosed

USB cable to the USB port on the UPS and an open USB port on

the computer.

2. With the UPS unit OFF and unplugged, plug your equipment

into the unit’s rear panel AC outlets. DO NOT plug a space heater,

vacuum cleaner, paper shredder or other large electrical device

into the UPS. The power demands of these devices will overload

and possibly damage the unit.

3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall

outlet). Make sure the wall branch outlet is protected by a fuse

or circuit breaker and does not service equipment with large

electrical demands (e. g. refrigerator, copier, etc.) Avoid using

extension cords. If used, the extension cord must be UL or CSA

Listed, minimum 14 AWG, 3-wire grounded, and rated for 15

Amps.

Installing Your UPS

4. Press and hold the power switch for 2 seconds to turn the

UPS on. The display will say “Initializing”, followed by the

normal operation screen.

5. The rear panel circuit breakers will open and power to the

connected equipment will be turned OFF if an overload is

detected. To correct this, turn the UPS off, unplug at least one

piece of equipment, wait 10 seconds, check to make sure that the

circuit breakers are reset, and turn the unit on.

6. The UPS will automatically charge the battery whenever it is

plugged into an AC outlet.

7. To maintain optimal battery charge, leave the UPS plugged

into an AC outlet at all times.

Note: To store your UPS for an extended period, cover it and

store with the battery fully charged. Recharge the battery every

three months to ensure battery life.

Specifications

Input

Voltage..............................................................................85 – 137 Vac
Frequency..............................................................................57 – 63 Hz

AC Power

Current Rating................................................................................12 A
Surge Protection...................................................................900 Joules
Overvoltage Shutoff, fast rise.................................................150 ± 5 V
Overvoltage Shutoff, slow rise................................................132 ± 5 V
Undervoltage Shutoff................................................................90 ± 5 V
Automatic Voltage Regulation,
Sensitive Mode Capture Range.............................................98 – 135 V
Automatic Voltage Regulation,
Sensitive Mode Output Range................................................120 ± 5%
Automatic Voltage Regulation,
Standard Mode Capture Range............................................93 – 145 V
Automatic Voltage Regulation,
Standard Mode Output Range..............................................120 ± 10%
Bank 1 EMI Filtration......................................66dB Max, 100kHz-2MHz
Bank 2 EMI Filtration......................................66dB Max, 100kHz-2MHz

UPS Output

Voltage...................................................120 ± 5 V Simulated Sine Wave
Frequency..............................................................................60 Hz ± 1%
UPS Output Capacity...........................................1000VA 600W @ 0.6pf
UPS Backup Time...................................................3 minutes at full load
Transfer Time...............................................................................< 10ms