Advanced operation, Rs-232 communications protocol & command set – Panamax BANKS WIRING MB1000 User Manual

Page 9

Advertising
background image

7

2. If the delay settings are the same for both IR1 and IR2, the IR2

code will be sent to both outputs 2 seconds after IR1.

3. The IR commands will also be transmitted immediately after

the battery charge falls below the critical load battery threshold.

This ensures that equipment will be shutdown properly if the

UPS’s load level is extremely high and the backup time would be

less than the selected IR output delay.

4. There is no IR output after the power is restored to the system.

To program IR output:

1. From the setup menu, turn the Menu Navigation Knob until

IR1 Setup is displayed. Push the Menu Navigation Knob to

select.

2. Turn the Menu Navigation Knob until IR1 Program is dis-

played.

3. The screen will display the message “READY TO SAMPLE

REMOTE”. Press the button on the remote.

4. If the signal was learned, then the screen will display the

message “IR1 SAMPLED” and advance to the “TEST IR” screen.

Press the navigation knob to test.

5.If the signal was not learned, the screen will display the mes-

sage “IR1 SAMPLE FAIL”, then it will return to the IR1 Program

screen. Repeat steps 3 and 4.

6.To program another IR device, from the Setup menu, turn the

Menu Navigation Knob until IR2 Setup is displayed. Follow

steps 3-5.

Advanced Operation

RS-232 Control with Open Protocol

The RS-232 serial interface can be used in the following ways:

1. Initial system setup. An installer can use a notebook comput-

er to set the variables within the Power Control software. Once

the setup is completed, the notebook computer can be discon-

nected. All settings are stored in the UPS.

2. Connection to a PC or Network: Functionality is very similar

to a standard UPS with a PC.

The UPS can provide continued power to maintain recording

capabilities of any number of devices in the event of a black out

or brown out. It is also capable of saving open documents and

shutting down the PC during extended power failures. This re-

quires a permanent RS232 connection to the PC and having the

Power Control software running in the background on the PC.

(Windows based OS only; Mac Energy Saver software compat-

ible)

3. Integration with sophisticated automation systems like AMX

and Crestron:

The serial communications command set and protocol is open

and is published later in this manual. This information can be

used by the automation system programmer for both UPS control

by the automation system and reporting of power events by the

UPS to the automation system.

RS-232 Communications Protocol &

Command Set