12

RS-232 Communications Protocol & Command Set

BATTERY LEVEL STATUS

Requests the battery level, expressed as a percentage of maxi-

mum (full charge).

Send Query to UPS:

?BATTERYSTAT<CR>

Action:

Load level will be displayed

Response:

$BATTERY = xxx<CR>

xxx is the battery charge level (percentage of maximum charge)

expressed in decimal format. If the value is less than 100, the

hundreds digit is represented with a 0.

____________________________________________
LIST CONFIGURATION

Requests a list of all configurable parameters and current settings.

Send Query to UPS:

?LIST_CONFIG<CR>

Action:

List of configurable parameters and

current settings will be displayed.

Response:

$BTHRESH = level<CR>

$BUZZER = mode<CR>

$AVR = mode<CR>

$FEEDBACK = mode<CR>

LINEFEED = mode<CR>

$BRIGHTNESS = xxx<CR>

$SCROLL_MODE = xxx<CR>

$SLEEP_MODE = xxx<CR>

____________________________________________
List of all commands and queries

Send Query to UPS:

?HELP<CR>

Action:

List of all commands and queries

will be displayed

Response:

!ALL_ON<CR>

!ALL_OFF<CR>

!SWITCH<CR>

!SET_BATTHRESH<CR>

!SET_BUZZER<CR>

!SET_AVR<CR>

!SET_FEEDBACK<CR>

!SET_LINEFEED<CR>

!RESET_ALL<CR>

!SET_BRIGHT<CR>

?VOLTAGE<CR>

!SET_SCROLLMODE<CR> ?LOADSTAT<CR>

!SET_SLEEPMODE<CR> ?BATTERYSTAT<CR>

?ID<CR>

?LIST_CONFIG<CR>

?OUTLETSTAT<CR>

?HELP<CR>

?POWERSTAT<CR>

_________________________________________
RESPONSES & MESSAGES

OUTLET STATUS CHANGE

CONDITION

RESPONSE

Outlet Bank 1 changes state $BANK1 = status<CR>

Outlet Bank 2 changes state $BANK2 = status<CR>

status = {ON, OFF}

_________________________________________
POWER BUTTON STATUS CHANGE

CONDITION

RESPONSE

Power Button changes

$BUTTON = status<CR>

ON/OFF status

status = {ON, OFF}

_________________________________________
POWER FAULT STATUS CHANGE

CONDITION

RESPONSE

Overvoltage State

$PWR = OVERVOLTAGE<CR>

Undervoltage State

$PWR = UNDERVOLTAGE<CR>

Lost Power State

$PWR = LOST POWER<CR>

Test Mode

$PWR = TEST<CR>

Recovery Mode

$PWR = RECOVERY<CR>

Normal Operation Mode $PWR = NORMAL<CR>

Low Battery

$LOWBAT<CR>

AVR Stage

$AVRSTATE = state<CR>

state = {BOOST, BUCK}

Remaining Backup Time $TIME = xxx<CR>

xxx = backup time

Battery State

$BATTSTATE = xxx<CR>

xxx = {CHARGE, DISCHARGE, FULL}

Power Control Software

Complete Instructions are available by clicking on Help on the

Power Control Software welcome screen.