4-6 System Administrator’s Guide

3. Select the sensor to calibrate (either Black Mark or On-Demand).

The black mark sensor is used with black mark supplies (supplies
with rectangular marks on the back side of the liner or on the supply).
The on-demand sensor is for peeled supplies, either die-cut or black
mark.

4. Tap Calibrate Sensor to calibrate the selected sensor.

If you select the Black Mark sensor, the printer feeds supply until
it detects a black mark to calibrate the sensor. When the
calibration is successful, a label prints: “Stock Sensor Calibration
Successful.”
If you select the On-Demand sensor, the printer feeds one or two
labels to calibrate the on-demand sensor.
As these tests are successfully performed, a window appears that
tells you if the calibration was successful or unsuccessful. Tap
OK.
If you calibrate the sensor, there is no need to calibrate the
supply. However, if you tap Calibrate Stock, two or three labels
are fed to calibrate the supply.

Note: If you want to feed a blank label, tap Feed.
5. Tap Back to return to the Print Engine Tests screen.

OR
Tap Done to return to the desktop.