Standards Compliance for SNMP Traps

B-4

7975-A2-GB20-40

December 1998

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical E1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:

Interface

enterpriseTestStart/Stop
Variable-Bindings

Possible Cause

DSL Network

H

ifIndex (RFC 1573)

H

ifAdminStatus (RFC 1573)

H

ifOperStatus (RFC 1573)

H

ifType (RFC 1573)

H

ifTestType (RFC 1573)

The following objects control tests
in SNMP-managed devices:

– noTest – Stops the test in

progress.

– testLoopLLB – Initiates a Local

Loopback.

– testLoopRLB – Initiates a

Remote Loopback.

– testSendMon511 – Initiates a

Send and Monitor 511 test.

– testSendLLBUp – Initiates an

LLB Up message to the remote
unit.

– testSendLLBDown – Initiates an

LLB Down message to the
remote unit.

H

enterpriseTest Start – Any
one of the following tests is
active on the interface:

– Line Loopback

– Repeater Loopback

– Remote Line Loopback

– Send and Monitor 511

H

enterpriseTest Stop – No tests
currently running on the
interface.

Synchronous
Data Ports

H

ifIndex (RFC 1573)

H

ifAdminStatus (RFC 1573)

H

ifOperStatus (RFC 1573)

H

ifTestType (RFC 1573)

The following objects control tests
in SNMP-managed devices:

– noTest – Stops the test in

progress.

– testLoopDCLB – Initiates a Data

Channel Loopback.

– testLoopDTLB – Initiates a Data

Terminal Loopback

– testSendDCLBUp – Initiates an

DCLB Up message to the
remote unit.

– testSendDCLBDown – Initiates

an DCLB Down message to the
remote unit.

H

enterpriseTest Start – Any
one of the following tests is
active on the port:

– Data Terminal Loopback

– Data Channel Loopback

– Remote Data Channel

Loopback

H

enterpriseTest Stop – No tests
currently running on the
interface.

Advertising