Send and monitor 511 – Paradyne Hotwire 7975 User Manual

Page 60

Advertising
background image

Testing

5-6

7975-A2-GB20-40

December 1998

Send and Monitor 511

The LTU initiates the test by lighting the Test LED sending a command to the
remote unit to send a 511 test pattern. When the remote unit detects the
command, it sends a 511 pattern and lights the front panel test LED. Each unit
will send and monitor the 511 pattern. The duration and results of the test are
displayed on the Network Test screen of each unit.

NOTE:

The send and monitor test is not a loopback test. Each unit independently
sends and monitors a 511 pattern.

98-15936

NTU/LTU

EIA-530

Port

All 1s

NTU/LTU

Local

Remote

All 1s

511 Pattern

CAP

511

Gen

511

Mon

CAP

511

Mon

511

Gen

Framer

Port

Interface

Framer

Port

Interface

511 Pattern

"

Procedure

To run a Send and Monitor 511 test:

1. Position the cursor at the Start command next to Send and Monitor 511 on

the Network Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop

command.

4. Press Enter.

When a Send and Monitor 511 test is active, a count of bit errors is displayed next
to the test duration, and the ResetMon virtual function key is available for use.
Type r or R or select the ResetMon virtual function key to reset the error count.

Advertising