Configuration Option Tables

A-15

7975-A2-GB20-40

December 1998

Table A-7.

SNMP Traps Options (2 of 2)

Enterprise Specific Traps

Possible Settings: Enable, Disable
Default Setting: Disable

Determines if SNMP traps are generated for enterprise-specific events.

Enable – SNMP traps are generated for

enterpriseSpecific events.

NOTE:

Refer to

Enterprise Specific Traps

in Appendix B,

Standards Compliance

for SNMP Traps

.

Disable – No enterprise-specific event traps are sent.

Link Traps

Possible Settings: Disable, Up, Down, Both
Default Setting: Both

Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.

Disable – No

linkUp or linkDown SNMP traps are generated.

Up – A

linkUp trap is generated when the 7975 Termination Unit recognizes that one of

the communication interfaces is operational.

Down – A

linkDown trap is generated when the 7975 Termination Unit recognizes a

failure in one of the communication interfaces.

Both – Sends trap messages for detection of both

linkUp and linkDown.

NOTE:

Refer to

linkUp and linkDown

in Appendix B, Standards Compliance for

SNMP Traps.

Link Trap Interfaces

Possible Settings: Network, SYNC, All
Default Setting: All

Determines if the SNMP

linkUp, SNMP linkDown, and interface-related

enterpriseSpecific traps are generated for the network interface and synchronous data
(DTE) port, or all.

Network – SNMP trap messages are generated for the network interface.

SYNC – SNMP trap messages are generated for the synchronous data (DTE) port.

All – SNMP trap messages are generated for the network interface and the
synchronous data (DTE) ports.