Testing

5-3

7975-A2-GB20-40

December 1998

Line Loopback

Line Loopback (LLB) loops the received signal on the network interface back to
the network without change.

98-15931

NTU/LTU

Network

Interface

All 1s

Port

Interface

Framer

EIA-530

Port

CAP

"

Procedure

To run a Line Loopback:

1. Position the cursor at the Start command next to Line Loopback on the

Network Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop

command.

4. Press Enter.

Line Loopback cannot be started when a Repeater Loopback, Data Channel
Loopback (DCLB), Remote DCLB, or network-initiated Line Loopback is in
progress.