Security, Overview, Ati access levels – Paradyne Hotwire 7975 User Manual

Page 73: Chapter 7, Security can limit ati access several ways. t

Advertising
background image

7-1

7975-A2-GB20-40

December 1998

Security

7

Overview

The 7975 Standalone Termination Unit provides several methods of security by
limiting user access to the ATI through option settings. You can:

H

Enable the Telnet Login Required option.

H

Limit the access by setting a Session Access Level option of Operator for the
Telnet Session.

H

Disable the access with the Telnet Session option.

See Table A-5,

Telnet Sessions Options

, in Appendix A,

Configuration Option

Tables.

ATI Access Levels

The 7975 Standalone Termination Unit has two access levels: Administrator and
Operator. The access level determines what functions are accessible, as shown
in Table 7-1.

Table 7-1.

Access Levels

ATI Access to Menu Functions

Administrator

Operator

Status

Read-Only

Read-Only

Test

Full Access

No Access

Configuration

Full Access

Read-Only

Control

Full Access

No Access

The effective access level is the more restrictive of the session access level or
the login access level.

Advertising