Configuration Option Tables

A-5

7975-A2-GB20-40

December 1998

Table A-2.

Synchronous Data Port Options (2 of 3)

Invert Transmit Clock

Possible Settings: Disable, Enable
Default Setting: Disable

Specifies whether the clock supplied by the 7975 Termination Unit on the TXC
interchange circuit DB (CCITT 114) is phase inverted with respect to the Transmitted
Data interchange circuit BA (CCITT 103). This configuration option is useful when long
cable lengths between the 7975 Termination Unit and the DTE are causing data errors.

Disable – Indicates TXC supplied by the 7975 Termination Unit on this port is not phase
inverted.

Enable – Indicates TXC supplied by the 7975 Termination Unit on this port is phase
inverted.

Send All Ones on Data Port Not Ready

Possible Settings: Both, Disable, DTR, RTS
Default Setting: Both

Specifies the conditions on the data port that determine when valid data is not being
sent from the DTE. When this condition is detected, all ones are sent to the network.

Both – Monitors both DTR and RTS. If either is interrupted, all ones are sent to the
network.

Disable – Disables the monitoring of interchange circuits from the DTE connected to
the synchronous data port.

DTR – Monitors the DTE Ready interchange circuit CD (CCITT 108/1/2). When DTR is
interrupted, all ones are sent to the network.

RTS – Monitors the Request-to-Send interchange circuit CA (CCITT 105). When RTS is
interrupted, all ones are sent to the network.

Action on Network LOS Alarm

Possible Settings: Halt, None
Default Setting: Halt

Specifies the action taken on the synchronous data port when an LOS (Loss Of Signal)
alarm is received on the network interface.

Halt – Stops the transmission of data on the data port and disables the data port when
an LOS alarm is received on the network interface. When LOS alarms are received, all
ones are sent on the Received Data interchange circuit BB (CCITT 104). The
Clear-to-Send interchange circuit CB (CCITT 106) is interrupted.

None – Makes the data port unaffected by LOS alarms received on the network
interface.

Network Initiated Data Channel Loopback

Possible Settings: Disable, Enable
Default Setting: Disable

Allows the initiation and termination of a Data Channel Loopback (DCLB) by the receipt
of a DCLB-actuate sequence or DCLB-release sequence from the network or far-end
device.

Disable – Ignores the DCLB-actuate and DCLB-release sequences for this port.

Enable – DCLB-actuate and DCLB-release sequences are recognized for this port.