Utility software, Network setup, Connection – Panasonic WJ-NT104 User Manual

Page 54

Advertising
background image

54

UTILITY SOFTWARE

■

Network Setup

For the network setup, you need to set the IP address
using the Utility Software provided and connect the WJ-
NT104 to a PC via the RS-232C port.

●

Connection

The COM1 port of the RS-232C interface is used for
setting the IP address. Your PC should be IBM-PC
compatible, have Windows95, Windows98 or Windows
NT4.0 installed, and have an RS-232C port.
Before installing the Utility Software provided, read the
Readme.txt file on Utility Software disc.

q Connect the RS-232C port on the front of the WJ-NT104

and the RS-232C port of the PC with an RS-232C
cable.

w Set bits #7 and #9 of the MODE selector to ON position

(leave the others on OFF), and then press the RESET
button on the front of the WJ-NT104.

e Click the

Start

button, point to

Programs

and then

WJ-

NT104 Utilities

, then click

Network Configuration

.

r To set the IP address: Enter the IP address into the

[IP

ADDRESS]

fields of the dialog box, then click the

[SET]

button. If the IP address has been set properly,

the response command REI and the IP address enter-
ed (in hexadecimal, 8-bit notation, e.g., REI:COA8000A
for IP address 192.168.0.10) should appear in the WJ-

NT104 RESPONSE

field. If a wrong number is shown,

click the

[SET]

button again.

t To set the netmask: Enter a set value into the

[NET-

MASK]

fields of the dialog box, then click the

[SET]

button. If the netmask has been set properly, the
response command REM and the set value entered (in
hexadecimal, 8-bit notation, e.g., REM:FFFFFF00 for
the set value 255.255.255.0) should appear in the WJ-

NT104 RESPONSE

field. If a wrong number is shown,

click the

[SET]

button again.

y To set the default gateway: Enter a set value into the

[DEFAULT GATEWAY]

fields of the dialog box, then

click the

[SET]

button. If the default gateway has been

set properly, the response command REG and the set
value entered (in hexadecimal, 8-bit notation, e.g.,
REG:COA80001 for the set value 192.168.0.1) should
appear in the

WJ-NT104 RESPONSE

field. If a wrong

number is shown, click the

[SET]

button again.

u Complete the setup by clicking the

[EXIT]

button.

i Return all switches on the MODE selector to OFF posi-

tion and then press the RESET button on the front of the
WJ-NT104.
This completes setup and return to the normal applica-
tion mode.

PC

RS-232C cable

WJ-NT104

9-pin D-sub connector

(female)

9-pin D-sub connector

(female)

1

2

3

4

5

6

7

8

Frame

1

2

3

4

5

6

7

8

Frame

Shield

Advertising