Model 3510 faceplate, 3500 series indicators and switches, Figure 3-1 – Paradyne 3510 User Manual

Page 24: Shows the 18 indicators and 4 pushbutton, And switches are listed in, Table 3-1, And their functions

Advertising
background image

COMSPHERE 3500 Series Data Service Units

3-2

March 1999

3510-A2-GN32-60

TEST

REM

PASS

FAIL/STR/DSBL

OK

OS/NS

TXD RXD RTS CTS DSR LSD

103

104

105

106

107

109

2.4/4.8

19.2/38.4

9.6

56/64

TP

LL

DL

RL

3510

496-12301-01

SPEED

Figure 3-1. Model 3510 Faceplate

Table 3-1

(1 of 3)

3500 Series Indicators and Switches

Name

Definition

Function

OK

Normal Operation

This green indicator lights when the DSU is
connected to the digital network or LADS and is
operating normally. It goes Off if the OS/NS
alarm indicator is active.

1

OS/NS

Out-of-Service/No Signal

This red indicator signals a network failure:

OS – Slow flash when Out-of-Service or
Out-of-Frame messages are received from
the network.

NS (No Signal) – Rapid flash when DSU is
not receiving signals from the network.

TEST

Test

This yellow indicator lights whenever the digital
network or a remote DSU initiates testing, or the
local TP, LL, DL, or RL key is pressed to start
testing. The test indicator flashes while tests are
being set up or taken down.

REM

Remote

This yellow indicator lights whenever a test
request is received from a remote DSU or the
digital network.

1

If the DSU has been placed in a Network Loopback, then both the OK and OS/NS indicators will be lit (the

TEST and REM indicators will also be lit).