Local loopback – dte test message test diagram, Local loopback – dte test message – Paradyne 3510 User Manual

Page 34

Advertising
background image

COMSPHERE 3500 Series Data Service Units

3-12

March 1999

3510-A2-GN32-60

Local Loopback – DTE Test Message

The Local Loopback is a data disruptive test used to

determine the proper functioning of the DTE to DSU
connection.

Local Loopback Overview

This loopback uses a test message provided by your

DTE. The DTE sends the message to the DSU’s
transmitter, where it is looped back to the receiver and
returned to the DTE (Figure 3-6). Check the returned
message for errors. Errors should be detected,
appropriately reported, and the problem cleared. The DSU
front panel does not display the test results.

Make sure the DTE cable is connected to the DSU and

the DSU is powered on. The DSU is not required to be
connected to the network.

To start the loopback, press the LL test switch; the

DTE sends the test message. To return the DSU to normal
after the loopback result is determined, press the LL test
switch.

Local Loopback Procedures

Follow the procedure in

Table 3-5

or

Table 3-6

to

perform a Local Loopback – DTE Test Message.

Local Loopback Results

For proper operation, the test message should be

received error free.

Figure 3-6. Local Loopback – DTE Test Message Diagram

Advertising