Selects source of timing signals (see, Table 4-4 – Paradyne 3510 User Manual

Page 60

Advertising
background image

COMSPHERE 3500 Series Data Service Units

4-20

March 1999

3510-A2-GN32-60

Table 4-3

(3 of 3)

Model 3510 and Model 3511 DSU Straps S1 through S5

Switch Selection

Function

1

Position

S5–1

S5–2

S5–3

S5–4

S5–5

S5–6

F

R

F

R

F

R

F

R

R

F

Provides separate signal and frame grounds (Model 3510 only)
Connects signal ground to frame ground* (Model 3510 only)

Disables test mode indication
Enables test mode indication on Pin 25 of EIA-232-D interface

Disables test mode indication
Enables test mode indication on Pin NN of V.35 interface

Not used (should be left open)

Disables DSR always on function
Enables DSR always on function

Disables diagnostic message clamping (Model 3510 only)
Enables diagnostic message clamping (Model 3510 only)

F = Front

R = Rear

1

Selections are the same for Model 3510 and Model 3511 unless otherwise noted.

Table 4-4

Timing Signal Source Selection for Both Model 3510 and Model 3511

S1–1

S1–2

Source

R

R

F

F

R

F

R

F

Digital Network

Tributary/Slave LADS

Internal LADS

External LADS

F = Front

R = Rear