Connecting to a v.35 interface – Paradyne 3510 User Manual

Page 49

Advertising
background image

Installation

4-9

3510-A2-GN32-60

March 1999

Connecting to a V.35 Interface

To connect a V.35 interface cable:

"

Procedure

1. Connect the 25-pin end of the V.35 adapter to the

bottom DTE connector on the rear connector plate
(refer to Figure 4-5). Tighten the thumbscrews on
both sides of the connector.

2. Connect the 34-pin end of the V.35 adapter to the

DTE’s V.35 interface cable. Tighten the screws on
both sides of the connector.

Installation of the V.35 interface cable is complete.

NOTE

For the V.35 connector, the
recommended maximum distance
between a DTE and a DSU is
nominally 1000 feet. For the
EIA-232 connector, the effective
shunt capacitance of the circuit,
measured at the DSU, including
the capacitance of the cable and
the DTE, must not exceed
2500 picofarads, as specified
in EIA-232-D.

25-Pin Connector

V.35 Adapter

V.35 Cable

Thumbscrews

99-16298

Figure 4-5. Model 3511 DSU V.35 Adapter Installation

(Feature Number 3000-F1-510)