Input/output signal settings – Panasonic AV-HS400AE User Manual

Page 75

Advertising
background image

7

4. Input/output signal settings

<Phase relationship between input signals and output signals>

(for 1080/59.94i format)

(Example 1)

F1

F2

F1

F2

F1

F2

F1

F2

Input signals
(non-synchronized)

1F (frame)

Sync signal (Ref)

Output signal

1

Output signal

2

(90H)

Output signal

2

(1F)

Max. 1F

Max. 2F

Max. 1F+90H

(Example 2)

F1

F2

F1

F2

F1

F2

F1

F2

Input signals
(non-synchronized)

1F (frame)

Sync signal (Ref)

Output signal

1

Output signal

2

(90H)

Output signal

2

(1F)

Max.

1F–90H

Max. 2F–90H

Max. 1F