Centronics interface signals – Printronix P9000 Series User Manual

Page 174

Advertising
background image

Interfaces

7-4

maximum data line length (cable length) from the controller (host computer) to the printer is

40 feet.

Centronics Interface Signals

Table 7-3 lists the Centronics interface connector pin assignments. Centronics interface sigĆ

nals between the computer and the printer are defined following the table.

Table 7-3. Centronics Interface Connector Pin Assignments

INPUT SIGNALS

OUTPUT SIGNALS

SIGNAL

PIN

SIGNAL

PIN

Data Line 1

Data Line 2

Data Line 3

Data Line 4

Data Line 5

Data Line 6

Data Line 7

Data Line 8

Data Strobe

Return

Return

Return

Return

Return

Return

Return

Return

Return

ACKNLG

SLCT

Busy

Chassis

Spare

Return

Return

PE

Ground

2

20

3

21

4

22

5

23

6

24

7

25

8

26

9

27

1

19

10

28

32, 13

12

11

29

17

30,31,

34,35,

36

Paper Instruction

Return

15

14

PE - A high true level from the printer to indicate the printer is in a fault condition.

SLCT - A high true level from the printer to indicate the printer is ready for data transfer and

the ON LINE switch has been activated.

Busy - A high true level from the printer to indicate the printer cannot receive data.

ACKNLG - A low true pulse from the printer indicating the character or function code has

been received and the printer is ready for the next data transfer.

Data Strobe - A low true, 100 ns minimum pulse from the host to clock data into the printer.

Data Lines - Eight standard or inverted levels from the host that define the data, which may

consist of a character or function code. Sensing Data Line 8 is controlled by printer configuraĆ

tion.

Paper Instruction (PI) - Optional VFU control signal from the host with the same timing and

polarity as the data lines. PI line sensing is controlled by printer configuration.

NOTE: The PI Line must be disabled (configuration option selected from the front

panel) if the host does not drive or control the PI Line. If the line is not controlled by the

host and sensing is enabled, rapid paper slewing will occur.