C-3
Appendix
Relative Humidity
Operating
10% to 90% (noncondensing)
Storage
5% to 95% (noncondensing)
Acoustic Noise
Less than 55 dBA (tested at 132 column, DP at 10 cpi per ISO 7779)
Electrical Characteristics
Input Power
Voltage
120 or 240 VAC
Phase
Single
Frequency
50 or 60 Hz
Power Rating
Nominal Standby
330 VA 60 Hz (200 Watts)
Nominal Operating
830 VA 60 Hz (520 Watts)
Dissipated Power Per Hour
Standby
680 BTUs
Printing
1,780 BTUs
Data Input Rate (maximum)
Dataproducts
500,000 characters per second
Centronics
200,000 characters per second
RS-232
Up to 19.2K Baud
RFI
Radio Frequency Interference Tested/Certified to RFI Standards FCC 15 Class A; VDE 0871
Class B; CSA C108.8-M1983 Class A.
Advertising