5 troubleshooting by error log, Error log display format – Philips KX-TAW848 User Manual

Page 117

Advertising
background image

4.1 Troubleshooting

Installation Manual

117

4.1.5

Troubleshooting by Error Log

When a major system error occurs in the PBX, the ALARM indicator on the front of the cabinet turns on red,
and the system logs the error information.

Error Log Display Format

Below is the display format of the error log. To see the error log using the KX-TAW848 Maintenance Console,
refer to the on-line help of the KX-TAW848 Maintenance Console.

Example: KX-TAW848 Maintenance Console

Example: Station Message Detail Recording (SMDR)

Description

Item

Description

1

Date

Date of the error detection

2

Time

Time of the error detection

3

Level

Major Alarm (MJ ALM):

Errors that affect the whole system operation, or result in system
failure

Minor Alarm (MN ALM):

Errors that affect certain part of system operation

4

Error Code

Three-digit error code

1

2

4

5

6

3

04/01/01 10:37AM MJ ALM #000 10000 MPR WDT overflow
04/01/01 11:07AM MN ALM #010 10000 AC power down
04/01/01 03:55PM MN ALM #392 10401 Clock master card selected

1

2

3

4

5

6

Advertising