4.1 Troubleshooting
122
Installation Manual
092*
CS connection
over
•
Too many CSs connected
•
Reduce the number of CSs
234
DPLL clock failure •
Main Board malfunction
•
Replace the PBX
251
MSG DSP failure
•
Optional service card
malfunction: MSG
•
See if the corresponding optional
service card is installed properly
•
Replace the corresponding optional
service card
305*
Data Link failure
•
Data link between the CS and
PBX failed
•
Check the connection between the CS
and PBX
310*
Port Link Failure
•
Voice Processing System
malfunction
•
Check the Voice Processing System
392
Clock master card
selected
•
Clock master card has been
changed to the one indicated
by the sub code
•
Check if the proper card is selected as
the new clock master card
510*
SMDR disconnect •
RS-232C cable not
connected
•
Breaking of RS-232C cable
•
Printer (terminal equipment)
malfunction
•
Check the RS-232C cable
•
Check the terminal equipment
Error Code
Error Message
PROBABLE CAUSE
SOLUTION