Philips KX-TAW848 User Manual

Page 122

Advertising
background image

4.1 Troubleshooting

122

Installation Manual

092*

CS connection
over

Too many CSs connected

Reduce the number of CSs

234

DPLL clock failure •

Main Board malfunction

Replace the PBX

251

MSG DSP failure

Optional service card
malfunction: MSG

See if the corresponding optional
service card is installed properly

Replace the corresponding optional
service card

305*

Data Link failure

Data link between the CS and
PBX failed

Check the connection between the CS
and PBX

310*

Port Link Failure

Voice Processing System
malfunction

Check the Voice Processing System

392

Clock master card
selected

Clock master card has been
changed to the one indicated
by the sub code

Check if the proper card is selected as
the new clock master card

510*

SMDR disconnect •

RS-232C cable not
connected

Breaking of RS-232C cable

Printer (terminal equipment)
malfunction

Check the RS-232C cable

Check the terminal equipment

Error Code

Error Message

PROBABLE CAUSE

SOLUTION

Advertising