Block operation, Overview of block operation, Continuous block operation – Panasonic MINAS A4P Series User Manual

Page 127: Operation setting, Continuous block operation procedure (example)

Advertising
background image

127

[Operation Setting]

Operation

Setting

Overview of Block Operation

This servo driver can perform the two types of block operations, i.e., continuous block operation and com-
bined block operation. These operations can be switched by 16.Pr54 (block operation type setting).

Continuous block operation : Several step operations can be performed continuously. Once an operation

starts, the operation continues to a specified point number.

Combined block operation : A step operation is performed according to combined several point numbers.

This is useful when you want to change the speed during a step operation.

Continuous Block Operation

If 16.Pr54 (block operation type setting) is “0” (continuous block operation) and the block setting of the point
number specified by point specifying input (P1IN to P32IN: CN X5 Pin 3, 4, 5, 6, 7 and 8) is “Block”, the step
operation is performed continuously in order from the specified point number to the block number of “Single”
block setting.

16.Pr54

(block operation type setting)

0

1

Description

Continuous block operation

Combined block operation

Point specifying input
(P1IN to P32IN)

Speed

Strobe signal input
(STB)

In-operation signal output
(BUSY)

In-deceleration output
(DCLON)

Positioning completion output
(COIN)

Point output
(P1OUT to P32OUT)

Transistor OFF

Transistor OFF

Transistor ON

Open

Open

Transistor ON

Transistor ON

Transistor OFF

MAX 10ms

MAX 10ms

MAX 10ms

Speed = VEL1

1 (01H)

1 (01H)

2 (02H)

3 (03H)

Acceleration
= ACC2

Deceleration = DEC1

Acceleration = ACC1

Speed
= VEL2

Moving to the absolute position “0”

Waiting time

5 seconds

[02]

[01]

[03]

Transistor OFF

Transistor OFF

Transistor ON

Moving to the absolute
position “500000”

Deceleration
= DEC2

Close

MIN10ms

Block Operation

Continuous block operation procedure (example)

1. Set a 16-bit positioning parameter and step parameter. (Refer to “Parameters Used in this Operation

Example” on page 128.)

2. Execute the homing. (Refer to “Homing Operation” on page 114.)
3. Specify the point 1 when the servo turns on and input the strobe signal input (STB: CN X5 Pin 24). Then,

an operation is performed continuously, e.g., [01] –> [02] –

> [03].

Advertising