Supplement, Reactor – Panasonic MINAS A4P Series User Manual

Page 189

Advertising
background image

189

[Supplement]

Supplement

C

B

A

(Mounting pitch)

D

6-1

R S T

NP

X Y Z

B

C

D

2-1

G

4-H

E

G

4-H

E

Fig.1

Fig.2

DV0P220
DV0P221
DV0P222
DV0P223
DV0P224
DV0P225
DV0P226
DV0P227
DV0P228
DV0P229

65
60
60
60
60
60
55
55
55
55

125
150
150
150
150
150

80
80
80
80

83

113
113
113
113
113

68
68
68
68

118
137
137
137
137
137

90
90
90
90

145
120
130
140
145
160

90
90
95

105

70
60
70
79
84

100

41
41
46
56

85
75
95
95

100
115

55
55
60
70

7(w) x 12(L)
7(w) x 12(L)
7(w) x 12(L)
7(w) x 12(L)
7(w) x 12(L)
7(w) x 12(L)

ш7.0
ш7.0
ш7.0
ш7.0

M4
M4
M4
M4
M4
M5
M4
M4
M4
M4

6.81
4.02

2

1.39

0.848
0.557

6.81
4.02

2

1.39

3
5
8

11
16
25

3
5
8

11

Fig.2

Fig.1

Part No.

A

B

C

D

E

F

G

H

I

Inductance

(mH)

Rated

current

(A)

F

(Mounting pitch)

F

(Mounting pitch)

A

(Mounting pitch)

MGMA

MSMA
MDMA
MHMA

MFMA

MSMA
MDMA
MHMA

MGMA

MFMA

MSMA
MDMA
MHMA

MGMA

MSMA
MDMA
MHMA

3-phase,

200V

900W

1.0kW
1.5kW

1.5kW

2.0kW

2.5kW

3.0kW

4.0kW

DV0P222

DV0P223

DV0P224

DV0P225

Motor

series

Power

supply

Rated

output

Part No.

MSMD

MQMA

MSMD

MQMA

MSMD

MQMA

MAMA

MFMA

MHMA
MSMD

MQMA

MAMA
MAMA

MFMA

MHMA
MSMD
MAMA

Single

phase,

100V

Single

phase,

200V

3-phase,

200V

50W to 100W

100W

200W to 400W

50W to 200W

100W to 200W

400W
500W

400W to 750W

400W

400W to 750W

400W

500W

750W

DV0P227

DV0P228

DV0P220

DV0P221

DV0P220

DV0P221

Motor

series

Power

supply

Rated

output

Part No.

Reactor

Harmonic restraint
On September, 1994, “Guidelines for harmonic restraint on heavy consumers who receive power through
high voltage system or extra high voltage system” and “Guidelines for harmonic restraint on household
electrical appliances and general-purpose articles” established by the Agency for Natural Resources and
Energy of the Ministry of Economy, Trade and Industry (the ex-Ministry of International Trade and Industry).
According to those guidelines, the Japan Electrical Manufacturers’ Association (JEMA) have prepared tech-
nical documents (procedure to execute harmonic restraint: JEM-TR 198, JEM-TR 199 and JEM-TR 201)
and have been requesting the users to understand the restraint and to cooperate with us. On January, 2004,
it has been decided to exclude the general-purpose inverter and servo driver from the “Guidelines for har-
monic restraint on household electrical appliances and general-purpose articles”. After that, the “Guidelines
for harmonic restraint on household electrical appliances and general-purpose articles” was abolished on
September 6, 2004.
We are pleased to inform you that the procedure to execute the harmonic restraint on general-purpose
inverter and servo driver was modified as follows.

1.All types of the general-purpose inverters and servo drivers used by specific users are under the control of

the “Guidelines for harmonic restraint on heavy consumers who receive power through high voltage sys-
tem or extra high voltage system”. The users who are required to apply the guidelines must calculate the
equivalent capacity and harmonic current according to the guidelines and must take appropriate counter-
measures if the harmonic current exceeds a limit value specified in a contract demand. (Refer to JEM-TR
210 and JEM-TR 225.)

2.The “Guidelines for harmonic restraint on household electrical appliances and general-purpose articles”

was abolished on September 6, 2004. However, based on conventional guidelines, JEMA applies the
technical documents JEM-TR 226 and JEM-TR 227 to any users who do not fit into the “Guidelines for
harmonic restraint on heavy consumers who receive power through high voltage system or extra high
voltage system” from a perspective on enlightenment on general harmonic restraint. The purpose of these
guidelines is the execution of harmonic restraint at every device by a user as usual to the utmost extent.

Advertising