Wiring of the main circuit (e and f-frame), System configuration and wiring – Panasonic MINAS A4P Series User Manual

Page 36

Advertising
background image

36

System Configuration and Wiring

Wiring of the Main Circuit (E and F-frame)

• Wiring should be performed by a specialist or an authorized personnel.
• Do not turn on the power until the wiring is completed.

Tips on Wiring

1) Take off the cover fixing screws, and detach the terminal cover.
2) Make wiring

Use clamp type terminals of round shape with insulation cover for wiring to the terminal block. For cable
diameter and size, rater to "Driver and List of Applicable Peripheral Equipments" (P.B14 and B15).

3) Attach the terminal cover, and fix with screws.

Fastening torque of cover fixed screw in less than 0.2 N•m.

Surge absorber

Motor

DC

24V

Power

supply

DC power supply
for brake

NFB

NF

MC

L1

U

V

W

E

L2

L3

r

t

P

B1

B2

U

V

W

L

Ground resistance : 100

max.

For applicable wire,
refer to P.B14 and B15.

Red

Black

Green
yellow

Yellow

(X2)

• Check the name plate of the driver for power

specifications.

• Provide a circuit breaker, or a leakage breaker. The

leakage breaker to be the one designed for
"Inverter" and is equipped with countermeasures for
harmonics.

• Provide a noise filter without fail.
• Provide a surge absorber to a coil of the Magnetic

Contactor. Never start/stop the motor with this
Magnetic Contactor.
Connect a fuse in series with the surge absorber.
Ask the manufacturer of the Magnetic Contactor for
the fuse rating.

• Provide an AC Reactor.

• Don't disconnect the short bar between B1 and B2.

Disconnect this only when an external regenerative
register is used.

• Match the colors of the motor lead wires to those of

the corresponding motor output terminals (U,V,W).

Avoid shorting and ground fault.

Don't connect the main power.

Earth-ground this.
• Connect the protective earth terminal ( ) of the

driver and the protective earth (earth plate) of the
control panel without fail to prevent electrical shock.

• Don't co-clamp the earth wires to the protective

earth terminal ( ) . Two terminals are provided.

Don't connect the earth cable to other inserting

slot, nor make them touch.

• Compose a duplex Brake Control Circuit so that the

brake can also be activated by an external
emergency stop signal.

• The Electromagnetic Brake has no polarity.
• For the capacity of the electromagnetic brake and

how to use it, refer to P.50, "Specifications of Built-in
Holding Brake".

• Provide a surge absorber.

Connect a 5A fuse in series with the surge absorber.

White

Fuse (5A)

Advertising