Adjustment, Auto-gain tuning action, How to operate – Panasonic MINAS A4P Series User Manual

Page 149: Parameters which are automatically set

Advertising
background image

149

[Adjustment]

Adjustment

10 1st position loop gain

11 1st velocity loop gain

12 1st velocity loop integration time constant

13 1st speed detection filter

14 1st torque filter time constant *2

15 Velocity feed forward

16 Feed forward filter time constant

18 2nd position loop gain

19 2nd velocity loop gain

1A 2nd velocity loop integration time constant

1B 2nd speed detection filter

1C 2nd torque filter time constant *2

20 Inertia ratio

27 Velocity observer

30 2nd gain action set up

31 1st control switching mode

32 1st control switching delay time

33 1st control switching level

34 1st control switching hysteresis

35 Position loop gain switching time

0

[

1

]

2

3

[

4

]

5

6

7

8

9

10

11

12

13

14

15

12

9

62

0

253

300

50

19

9

999

0

253

0

1

10

30

50

33

20

32

18

31

0

126

300

50

38

18

999

0

126

0

1

10

30

50

33

20

39

22

25

0

103

300

50

46

22

999

0

103

0

1

10

30

50

33

20

48

27

21

0

84

300

50

57

27

999

0

84

0

1

10

30

50

33

20

63

35

16

0

65

300

50

73

35

999

0

65

0

1

10

30

50

33

20

72

40

14

0

57

300

50

84

40

999

0

57

0

1

10

30

50

33

20

90

50

12

0

45

300

50

105

50

999

0

45

0

1

10

30

50

33

20

108

60

11

0

38

300

50

126

60

999

0

38

0

1

10

30

50

33

20

135

75

9

0

30

300

50

157

75

999

0

30

0

1

10

30

50

33

20

162

90

8

0

25

300

50

188

90

999

0

25

0

1

10

30

50

33

20

206

115

7

0

20

300

50

241

115

999

0

20

0

1

10

30

50

33

20

251

140

6

0

16

300

50

293

140

999

0

16

0

1

10

30

50

33

20

305

170

5

0

13

300

50

356

170

999

0

13

0

1

10

30

50

33

20

377

210

4

0

11

300

50

440

210

999

0

11

0

1

10

30

50

33

20

449

250

4

0

10

300

50

524

250

999

0

10

0

1

10

30

50

33

20

557

310

3

0

10

300

50

649

310

999

0

10

0

1

10

30

50

33

20

Stiffness value

represents parameters with fixed value. Default for A to C-frame is 4, and 1 for D to F-frame.

*2 Lower limit for stiffness value is 10 for 17-bit encoder, and 25 for 2500P/r encoder.

Title

Pr

No.

Estimated load inertia ratio

Auto-Gain Tuning Action

(1) In the normal mode auto-gain tuning, you can set up the response with machine stiffness No..

Machine stiffness No.

• Represents the degree of machine stiffness of the customer's machine and have values from o to 15.

You can set a higher No. to the high stiffness machine and set up a higher gain.

• Usually start setting up with a lower value and increase gradually to repeat auto-gain tuning in the

range where no oscillation, no abnormal noise, nor vibration occurs.

(2) This tuning repeats max. 5 cycles of the action pattern set with SV.Pr25 (Normal auto tuning motion

setup). Action acceleration will be doubled every one cycle after third cycle. Tuning may finish, or action
acceleration does not vary before 5th cycle depending on the load, however, this is nor an error.

How to Operate

(1) Set up the action pattern with SV.Pr25.
(2) Shift the load to the position where no hazard is expected even though the action pattern which is set

with SV.Pr25 is executed.

(3) Prohibit the command entry. (Do not enter the action command during the normal mode auto-gain tuning.)
(4) Turn to Servo-ON.
(5) Start up the auto-gain tuning. Use the "PANATERM

®

".

(6) Adjust the machine stiffness to the level at which no vibration occurs and obtain the required response.
(7) Write the result to EEPROM, if it is satisfactory.