Figure 3-10, Mode 1 output timing, Mode 2 bidirectional timing – National Instruments DAQCard-1200 User Manual

Page 42

Advertising
background image

Chapter 3

Signal Connections

DAQCard-1200 User Manual

3-20

© National Instruments Corporation

Mode 1 Output Timing

Figure 3-10 shows the timing specifications for an output transfer in
mode 1.

Figure 3-10. Mode 1 Timing Specifications for Output Transfers

Mode 2 Bidirectional Timing

Figure 3-11 shows the timing specifications for bidirectional transfers in
mode 2.

Name

Description

Minimum

Maximum

T1

WRT* = 0 to INTR = 0

250

T2

WRT* = 1 to output

200

T3

WRT* = 1 to OBF* = 0

150

T4

ACK* = 0 to OBF* = 1

150

T5

ACK* pulse width

100

T6

ACK* = 1 to INTR = 1

150

All timing values are in nanoseconds.

WRT*

OBF*

INTR

ACK*

DATA

T1

T2

T3

T4

T5

T6