Figure 3-11 – National Instruments DAQCard-1200 User Manual

Page 43

Advertising
background image

Chapter 3

Signal Connections

© National Instruments Corporation

3-21

DAQCard-1200 User Manual

Figure 3-11. Mode 2 Timing Specifications for Bidirectional Transfers

Name

Description

Minimum

Maximum

T1

WRT* = 1 to OBF* = 0

150

T2

Data before STB* = 1

20

T3

STB* pulse width

100

T4

STB* = 0 to IBF = 1

150

T5

Data after STB* = 1

50

T6

ACK* = 0 to OBF = 1

150

T7

ACK* pulse width

100

T8

ACK* = 0 to output

150

T9

ACK* = 1 to output float

20

250

T10

RD* = 1 to IBF = 0

150

All timing values are in nanoseconds.

T1

T6

T7

T3

T4

T10

T2

T5

T8

T9

WRT *

OBF *

INTR

ACK *

STB *

IBF

RD *

DATA