Mode 1 Input Timing

Timing specifications for an input transfer in mode 1 are shown in
Figure 4-13.

Figure 4-13. Timing Specifications for Mode 1 Input Transfer

Name

Description

Minimum

Maximum

T1

STB* Pulse Width

100

T2

STB* = 0 to IBF = 1

150

T3

Data before STB* = 1

20

T4

STB* = 1 to INTR = 1

150

T5

Data after STB* = 1

50

T6

RD* = 0 to INTR = 0

200

T7

RD* = 1 to IBF = 0

150

All timing values are in nanoseconds.

DATA

RD *

INTR

IBF

STB *

T1

T2

T4

T7

T6

T3

T5