Appendix – National Instruments 700 User Manual

Page 50

Advertising
background image

© National Instruments Corporation

B-1

DAQCard-700 User Manual

Appendix B
Differences between the PC-LPM-16 and the
DAQCard-700

This appendix contains a summary of differences between the PC-LPM-16 and the
DAQCard-700 that may be relevant to you if you are a current PC-LPM-16 user. For a summary
of programming differences, refer to the DAQCard-700 Register-Level Programmer Manual.

The DAQCard-700 is compatible with the PC-LPM-16. Software developed for the PC-LPM-16
using NI-DAQ or LabWindows routines, as well as LabVIEW virtual instruments (VIs) for the
PC-LPM-16, typically work with the DAQCard-700 without modification. The following table
summarizes the significant differences.

Functionality

PC-LPM-16

DAQCard-700

FIFO read

Two, 8-bit words

One, 16-bit word

FIFO buffer size

16 samples

512 samples

Maximum sample rate

50 kS/s

100 kS/s

Supply voltages at I/O connector

+5 V, +12 V, -12 V

+5 V

Maximum input voltage rating

±

45 V

±

30 V

ADC calibration

hardware calibration

software calibration

Timer chip

MSM82C53

MSM82C54*

Maximum timer source frequency

8 MHz

10 MHz

Input modes

single ended

single ended, differential

Input ranges

±

5 V,

±

2.5 V, 0-10 V,

±

10 V,

±

5 V,

±

2.5 V,

0-5 V, jumper selectable

software selectable

*

The MSM82C54 timer used in the DAQCard-700 is compatible with the MSM82C53.