SCXI-1127/1128 User Manual

behind slots 3 and 4 you have connected the rows between slot 3 and 4
which creates a 4

× 16 matrix. Now install the two 1-slot adapters behind

slots 1 and 2. Connect the two 1-slot adapters together with an 8-position
HVAB plug. Do not connect the 2-slot HVAB-backplane adapter to the
1-slot adapters as this would create a 4

× 32 matrix. You now have created

two independent 4

× 16 matrices. Finally, to create a 8 × 16 matrix you must

connect the 16 columns of each 4

× 16 matrix through the SCXI-1332

terminal block by using either matrix expansion cables or by wiring the
terminal blocks by hand.