Norton Abrasives C6136 User Manual

Page 44

Advertising
background image

44

the probe comes in contact with "HOT" electrical component. They
are easily obtained from automotive jobbers or discount stores.

c. Continuity Light:

Continuity Light is like a test light but contains its own battery power
source. It is used for testing electrical circuits when the components
are not connected to a battery. They are easily obtained from
discount stores or electrical jobbers at modest cost.

d. Volt Meter:

A DC volt meter, as used in automotive repair business, is a good
investment for trouble shooting problems that are related to low
voltage. They are used in two ways:

1. One probe is grounded while the other is used to probe the "HOT"

leads; the meter shows the voltage available at the point where
the second probe is connected.


2. Second: They can be used to measure a voltage drop in a wire; in

probe is connected to one end and the remaining to the other
end; the reading is the voltage drop.

e. OHM Meter:

An OHM meter is used to measure resistance and is very useful tool
when working on wire circuits and solenoid coils. On some coils the
wire resistance is up to a level where a DC test light might show an
open circuit and it really is not so. An infinite meter reading on any
test light shows that the circuit is open. A coil test, however, will
always show some value of resistance but it must not be infinite. All
tests conducted with an OHM meter must be done with the battery
disconnected from the system.

10. Hydraulic Fluid

a. The Purpose of Oil:

The main purpose of hydraulic fluid is to transfer power from the
pump to the actuators but it must also perform many other tasks
which are critical to a well designed system. First the oil must have
good lubricity or be "slippery" so that the friction will be as low as
possible to metal to metal wearing at a minimum. Second, the
viscosity or "thickness" must be in the proper range at the operating
temperature so that unwanted leakage will be at a minimum, but will
still allow the oil to lubricate the close fitting parts in the system. (Oil
that is too thin will leak past seals, valve spools and the gears; oil that
is too thick will not flow properly and cause the pump to cavitate or
starve.) Third, the oil must be compatible with the seals used in the
system. Fourth, there should also be additives in the oil to slow down
the effects of rust, oxidation (oxygen in the air combining with the oil

Advertising