Hardware Overview of the NI PXI-7831R

NI PXI-7831R User Manual

2-2

ni.com

Figure 2-2. Parts Locator Diagram for the NI PXI-7831R

Analog Input

The NI PXI-7831R has eight independent, 16-bit AI channels that can be
simultaneously sampled or sampled at different rates. The input mode is
software configurable, and the input range is fixed at ±10 V. The converters
return data in two’s complement format. Table 2-1 shows the ideal output
code returned for a given AI voltage.

Table 2-1. Ideal Output Code and AI Voltage Mapping

Input Description

AI Voltage

Output Code (Hex)

(Two’s Complement)

Full-scale range –1 LSB

9.999695

7FFF

Full-scale range –2 LSB

9.999390

7FFE

SW1