Connecting peripherals to the server – Nortel Networks Server 600r User Manual

Page 28

Advertising
background image

28

Chapter 4 Installing the server and peripheral devices

To install the server

Step

Action

1

Place the 600r server in its chosen location. If you are installing
the server in a rack cabinet, follow the instructions provided with
the slide rails.

Note: The DS30X cable that connects the NTRH40AA MPB96
board to the MGate cards is 20 m (60 feet) long. With this cable,
you can place the server in a different room from the Meridian
1 switch or CS 1000 system.

The DS30 cables that connect the NTRH40CA MPB96 board to
the NTRB18DA MGate cards can be up to 600 m (1968 feet)
long. With this cable you can place the server in a different
building from the Meridian 1 switch or CS 1000 system.

2

Locate the external SCSI terminator (included loose within the
server shipping carton). Connect the terminator to the rear SCSI
port labeled C in

Figure 7 "Rear panel" (page 29)

. For an illustration

of the SCSI terminator, see the item labeled Server terminator in

Figure 8 "SCSI tape drive with terminator" (page 31)

.

CAUTION

It is imperative that you install the terminator to ensure reliable
server operation. Failure to do so will result in an inability to load
the operating system.

3

Connect peripheral devices as described in this chapter.

—End—

What is next?

Connect peripheral devices as described in this chapter.

Connecting peripherals to the server

Rear panel connectors

The following diagram shows the connectors on the rear panel of the 600r.

Nortel CallPilot

600r Server Hardware Installation

NN44200-307

01.03

Standard

5.0

14 May 2008

Copyright © 2007-2008, Nortel Networks

.