NI cDAQ-9172 User Guide and Specifications

Debounce filter settings ......................... Selectable per input:

125 ns, 6.425 µs, 2.56 ms, disable,
high and low transitions

Timing input frequency.......................... 0 to 20 MHz

Timing output frequency........................ 0 to 20 MHz

General-Purpose Counter/Timers (Slots 5 and 6 Only)

1

Number of counter/timers ...................... 2

Resolution .............................................. 32 bits

Counter measurements ........................... Edge counting, pulse,

semi-period, period,
two-edge separation

Position measurements........................... X1, X2, X4 quadrature encoding

with Channel Z reloading;
two-pulse encoding

Output applications ................................ Pulse, pulse train with dynamic

updates, frequency division,
equivalent time sampling

Internal base clocks ................................ 80 MHz, 20 MHz, 100 kHz

External base clock frequency ............... 0 to 20 MHz

Base clock accuracy ............................... 50 ppm

Output frequency.................................... 0 to 20 MHz

Inputs...................................................... Gate, Source, HW_Arm, Aux,

A, B, Z, Up_Down

Routing options for inputs...................... Any PFI, analog trigger,

many internal signals

FIFO ....................................................... 2 samples

Data transfers ......................................... High-speed data stream,

programmed I/O

1

Requires correlated digital I/O modules installed in the appropriate slot(s).