NI cDAQ-9172 User Guide and Specifications

82

ni.com

Environmental

The NI cDAQ-9172 chassis is intended for indoor use only. For outdoor
use, mount the system in a suitably rated enclosure.

Operating temperature

1

(IEC-60068-2-1 and IEC-60068-2-2) .....–20 to 55 °C

Storage temperature
(IEC-60068-2-1 and IEC-60068-2-2) .....–40 to 85 °C

Ingress protection ...................................IP 30

Operating humidity
(IEC-60068-2-56) ...................................10 to 90% RH, noncondensing

Storage humidity
(IEC-60068-2-56) ...................................5 to 95% RH, noncondensing

Maximum altitude...................................2,000 m

Pollution Degree (IEC 60664) ................2

Shock and Vibration

To meet these specifications, you must panel mount the NI cDAQ-9172
system and affix ferrules to the ends of the terminal lines.

Operational shock ...................................30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random vibration

Operating .........................................5 to 500 Hz, 0.3 g

rms

Nonoperating ...................................5 to 500 Hz, 2.4 g

rms

(Tested in accordance
with IEC-60068-2-64.
Nonoperating test profile
exceeds the requirements of
MIL-PRF-28800F, Class 3.)

1

When operated in temperatures below 0 °C, you must use the PS-5 power supply, or another power supply rated for below 0 °C.