Chapter 1 Overview

312755-G Rev 00

Front panel locking screws

The front panel locking screws allow you to open the front panel to access the
alarm module. The alarm module contains jumpers that you use to configure your
system alarm parameters.

For information about configuring your system alarm parameters, see

“Accessing

the alarm module” on page 30

.

Back panel

Figure 5

shows the BIP back panel configuration (plastic back cover not shown).

Descriptions of the back panel components follow the figure.

Figure 5 Back panel components

Shelf alarm connectors (upper and lower shelves)

The shelf alarm connectors allow you to configure the BIP to control more than
one 8010co chassis.

Note: The BIP ships from the factory with default alarm configurations
set for a single chassis in the lower shelf of the rack. If you install a
second chassis, you must also configure the jumper on the alarm module
to support that configuration.

See “Accessing the alarm module” on

page 30

for information about jumper settings for your configuration.

10367EA

1 = J1 Upper shelf alarm connector
2 = J2 Lower shelf alarm connector

3 = J3 Central office alarm "in"
4 = J4 Central office alarm "out"

5 = J5 Standalone office alarm connector
6 = TB1 Power terminal block

3 2

PS (+)

Lower Shelf

PS (+)

Upper Shelf

PS (-)

Lower Shelf

PS (-)

Upper Shelf

A/B Input Feed

Returns

– 48 VDC

A/B Input Feeds

1 3 2 1

3 2 1 3 2 1

A

2

A

1

B

1

B

2

6

1

2

3

4

5