Diagnosing and correcting the problem, Diagnosing and correcting the – Nortel Networks 8010co User Manual

Page 70

Advertising
background image

70

Chapter 3 Problem solving

312755-G Rev 00

Diagnosing and correcting the problem

Before you perform the problem-solving steps in this section, complete the
following steps:

1

Set the switches for all power supplies in the upper and lower chassis to the
off position (O = Off).

2

Set the six circuit breakers on the BIP front panel to the off position (O = Off).

3

Check that all cables are installed properly, and that all power supplies are
firmly seated in their bays.

4

Set the six circuit breakers on the BIP front panel to the on position (| = On).

5

Set the switches for all power supplies in the upper and lower chassis to the on
position (| = On).

6

Verify the following LEDs on the BIP:

— The (white) POWER Indicator on the BIP front-panel is on.

— The (green) shelf alarm cable validation LED is on steady.

7

Verify the following LEDs on the 8010co chassis:

— The (green) power supply LEDs for each power supply in both the upper

and lower chassis are on.

— The chassis fans are powering up.

8

If the problem still persists, go to the next section,

“Corrective actions” on

page 71

.