Connecting the power supply cables to the bip, Figure 32, Attaching power supply cable leads to the bip – Nortel Networks 8010co User Manual

Page 49

Advertising
background image

Chapter 2 Installation

49

Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis

Connecting the power supply cables to the BIP

To connect the power supply cables to the BIP:

1

Locate one of the power supply cables.

2

Match the labeled tag on the power supply cable with the correct location on
the power terminal block (

Figure 32

).

The power terminal block label indicates a location for the positive and
negative power supply leads for both the upper shelf and lower shelf power
supplies.

3

Loosen the appropriate power terminal block screw, and then insert the cable
lead (item 1 in

Figure 32

). Tighten the screw securely.

Item 2 in

Figure 32

shows the negative cable lead from power supply 1 in the

upper shelf correctly connected to the power terminal block.

Figure 32 Attaching power supply cable leads to the BIP

10393FA

3 2

PS (+)

Lower Shelf

PS (+)

Upper Shelf

PS (-)

Lower Shelf

PS (-)

Upper Shelf

A/B Input Feed

Returns

– 48 VDC

A/B Input Feeds

1 3 2 1

3 2 1 3 2 1

A

2

A

1

B

1

B

2

3

+DC PS1 Upper

-DC PS1 Upper

1

2

1 = Positive lead wire from power
supply 1, upper shelf
2 = Negative lead wire from power
supply 1, upper shelf

3 = Power terminal block label