APPENDIX A MIPS III INSTRUCTION SET DETAILS

584

Preliminary User’s Manual S15543EJ1V0UM

TNE

Trap If Not Equal

TNE

rs

SPECIAL

0 0 0 0 0 0

rt

code

31

26 25

21 20

16 15

0

6

5

5

10

TNE

1 1 0 1 1 0

6

6 5

Format:

TNE rs, rt

Description:

The contents of general register

rt are compared to general register rs. If the contents of general register rs are not

equal to the contents of general register

rt, a trap exception occurs.

The code field is available for use as software parameters, but is retrieved by the exception handler only by loading

the contents of the memory word containing the instruction.

Operation:

32, 64 T:

if GPR [rs]

≠ GPR [rt] then

TrapException

endif

Exceptions: