Master Roll Replacement

77

4

Master Roll Replacement

The Master End indicator (

C) is lit

when it is time to replace the master
roll.

A

Open the original tray.

Note

❒ Lift the original tray release le-

ver and lift the original tray.

B

Open the right side cover.

C

Open the plotter cover.

D

Remove the used master roll and
pull out both spools. Then, insert
both spools into a new master
roll.

Note

❒ When the Master End indicator

lights, it is necessary to replace
the master roll even if some
master remains on the old roll.

E

The new master roll must be posi-
tioned as shown in the illustra-
tion.

TSLH01SE

TSLH02EE

TSLT010E

TSLH01XE

SilverV-gb.book Page 77 Monday, May 15, 2000 3:32 PM