Subaru Robin Power Products RG2800I User Manual

Page 23

Advertising
background image

– 20 –

(3) DIODE RECTIFIER

The circuit inside the diode rectifiers is as shown in the chart above.

Check continuity between each terminal by using a circuit tester.

The rectifier is normal when continuity is as follows:

Diode rectifier

Circuit tester

Yellow

Yellow

Yellow

Yellow

Gray

Gray

Orange

Orange

Yellow

Yellow

Orange

Gray

Apply black needle of the circuit tester

Continuity

-

Yellow

Checking table for analogue circuit tester

Analogue circuit tester

Continuity

No continuity

Yellow

Apply red needle
of the circuit tester

Continuity

Continuity

Orange

-

No continuity

No continuity

-

Continuity

No continuity

No continuity

No continuity

-

No continuity

Gray

Yellow

Yellow

Orange

Gray

Apply red needle of the circuit tester

Continuity

-

Yellow

Checking table for degital circuit tester

Degital circuit tester

Continuity

No continuity

Yellow

Apply black needle
of the circuit tester

Continuity

Continuity

Orange

-

No continuity

No continuity

-

Continuity

No continuity

No continuity

No continuity

-

No continuity

Gray

(4) AC RECEPTACLES

Check that no live part or wire or plastic part is burnt.

NOTE 1 : Because of the difference of measuring method between the analogue circuit tester and the digital circuit

tester, polarity of tester needles should be reversed.

NOTE 2 : "Continuity" means forward direction characteristics of the diode, and different from short circuit condition

(in which a pointer of the tester goes out of its normal scale), shows resistance to some extent.

When results of the checking indicates failure even in one section, replace with a new one.

NOTE 3 : Some analogue testers like "Simpson" brand operate as some as digital testers.