Subaru Robin Power Products RG2800I User Manual

Page 39

Advertising
background image

– 36 –

5-3-22 RECOIL STARTER

Loosen the three M6 bolts and remove the recoil

starter.

M6 x 18mm Flange bolt : 3pcs.

Tools : 10mm Box wrench

NOTE : Refer to section 5-5 for further instruction for

disassembly/reassembly procedures of recoil

starter.

Recoil starter

5-3-23 BOTTOM EXTENSION PLATE

Loosen the four M8 bolts and remove the bottom

extension plate.

M8 x 33mm Flange bolt for crankcase side : 2 pcs.

M8 x 12mm Flange bolt for blower housing side : 2 pcs.

Tools : 12mm Box wrench

Bottom extension plate

5-3-24 BLOWER HOUSING

(1) Loosen the four M& bolts and remove the

Separator (A/C) and Separator (SEL) from Blower

Housing. (for the soundproof type only)

M6 x 8mm Flange bolt : 3pcs.

M6 x 12mm Flange bolt: 1 pce.

Tools : 10mm Box wrench

(2) Loosen the four M6 bolts and remove the blower

housing.

M6 x 35mm Bolt : 1pce.

M6 x 45mm Bolt : 3pcs.

Tools : 10mm Box wrench

Blower housing

M6x35mm Bolt

M6x45mm
Bolt

Separator
(SEL)

Separator
(A/C)

Advertising
This manual is related to the following products: