Subaru Robin Power Products RG2800I User Manual

Page 28

Advertising
background image

5-3-8 WIRE BAND

Cut the wire bands that are binding wires behind the
control panel.

For electric start models, cut the wire band that is binding
battery cables also.

Tools : Nipper

Wire band

(3) Loosen the five bolts and remove the cover bracket

from the inverter unit.

M6 x 12mm Flange bolt 2pcs.

M6 x 18mm Flange bolt 2pcs.

M6 x 25mm AY Bolt 1pce.

NOTE : At this step, electric wires are still connected to

the control panel. Therefore, do not try to

separate the control panel forcedly. Separate the

control panel after removing fuel tank at "5-3-9

FUEL TANK".

Muffler cover

(Rear)

5-3-7 REAR COVER

(1) Remove the muffler cover.

M6 x 18mm Flange bolt 6pcs.

Tools : 10mm Box wrench

Rear cover
(Upper )

(2) Remove the upper rear cover.

– 25 –