Omnitron Systems Technology iConverter Network Management Module User Manual

Page 2

Advertising
background image

800-675-8410 • 949-250-6510 • www.omnitron-systems.com • [email protected] • 140 Technology Dr. • Irvine, CA 92618

Trademarks are owned by their respective companies. iConverter and NetOutlook are registered trademarks of Omnitron Systems Technology, Inc.

Specifications subject to change without notice. ©2008 Omnitron Systems Technology, Inc. All rights reserved.

091-18000-001H

12/08

Alarms / Traps

Warm Start

Link Up/Down

Chassis Insertion/Removal

Authentication Failure

DIP-Switch Configuration Change

Software Configuration Change

Temperature Out-of-Range

Power Supply Out-of-Range

Power Supply Insertion/Removal

Chassis Reset

Module Reset

Module Insertion/Removal

Port Link State Change

Redundancy Primary Up/Down

Redundancy Secondary Up/Down

FTP Session Open/Close

Telnet Session Open/Close

Dying Gasp (Power Loss Trap)

Active Controls

Link Propagate/Link Segment

Remote Fault Detection

Module Name

Chassis Name and Number

IP Address

802.3ah OAM Enable

Secure IP-less OAM Enable

Subnet Mask

Gateway

Management Port Disable

Alarm Threshold Setting

Download Software via FTP

Reset Chassis

Telnet

Trap IPs

FTP Enable

Password Selection

Soft Switch Reload

IP-less management requires an NMM in the core chassis, and
a media converter with integrated management installed at each
remote end of the IP-less managed link. An

iConverter

10/100M2

plug-in module is installed in the 19-Module chassis, and
connected via the fiber link to a standalone 10/100M2 Network
Interface Device (NID). This configuration enables the 19-Module
master chassis to establish an IP-less management channel
between the 10/100M2 link partners. The IP address
resides only at the network core, and does not exist on the
customer network.

Model

Description

8000-0

iConverter NMM Module w/ Dying Gasp Support

8080-3

NMM Cascade Cable (3 ft.)

8081-3

NMM Serial Cable (DB-9, 3 ft.)

Model Type

NMM

Protocols

IP, UDP, SNMPv1, SNMPv2c, SNMPv3,

Telnet, TCP, FTP, ARP, ICMP, 802.3ah

Connectors

RJ-45, DB-9

Controls

UTP cross-over, Frontplane / Backplane

LED Displays

Power, Power Supply (3), UTP link,

Master, Slave, Mgt. Poll

Supported MIBs

RFC1155, RFC1156, RFC1157,

RFC1212, RFC1213, OST MIB

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

Compliance

UL, CE, FCC Class A, NEBS 3

Power Requirement

0.32A @ 3.3VDC (typical)

Temperature

Standard: 0 to 50º C

Wide: -40 to 60º C

Storage: -40 to 80º C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

786,000

Chassis Information

Part Number

Serial Number

Revision

Description

Chassis Status

Power Status

Power Output Voltage

Chassis Temperature

Module Status

Module Power

Link Status

Active Port

Diagnostic Status

Management

Module Information

Module Type

Slot Occupied

Part Number

Serial Number

Configuration

Revision

Ports on Module

User-defined Identifier

Advertising