Fireplace size requirements – Quadra-Fire QVI-35FB-S User Manual

Page 17

Advertising
background image

Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08

17

5

5

Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fi replace opening requirements are shown in
Figure 5.1.

WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.

• The fi rebrick (refractory), glass doors, screen rails, screen

mesh and log grates can be removed from a factory
built fi rebox in order to gain minimum gas insert opening
requirements.

• Any smoke shelves, shields and baffl es may be removed

from the factory built fi rebox if attached with mechanical
fasteners.

Figure 5.1 Fireplace Opening

In addition to these dimensions, also reference Mantel
and Wall Projections (Section 5.B).

B

2 in.

50.8 mm

A

C

TOP VIEW

D

FRONT VIEW

MINIMUM FIREPLACE SIZE

Location

QVI-35FB-S

Inches

Millimeters

A

Front Width

35

889

B

Rear Width

22-5/8

574.7

C

Depth

14-1/8

358.8

D

Height 25-3/4

654

* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102

mm) to minimum fi replace height for bends in vent pipe.

• The metal fl oor of the solid fuel fi rebox may be removed to

facilitate the installation of the insert. The appliance may
not be placed directly on the base of the outer wrap, a 1/4
inch airspace must be provided between the insert and
the fl oor of the outer wrap. Use the levelling legs to raise
the insert a minimum of 1/4 inch. The original fi replace
may never be returned to solid fuel in this condition.
The sidewalls and top structure of the fi rebox may not
be altered with the exception of removable baffl es and
dampers.

• Cutting of any sheet metal parts of the fi replace in which

the gas fi replace insert is to be installed is prohibited,
except the fl oor as tested for and as noted above.