Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08

33

H. Air Shutter Setting

Air shutter settings should be adjusted by a qualifi ed in-
staller at the time of installation. The air shutter is set at
the factory for minimum vertical vent run. Adjust air shut-
ter for longer vertical runs.

NOTICE: If sooting occurs, provide more air by opening
the air shutter.

Figure 12.3 Fixed Glass Assembly

G. Fixed Glass Assembly

Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fi replace with glass removed, cracked,

broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

• There are two glass latches securing the bottom of the

glass assembly.

• Release the latches by pulling forward and retracting

away from the glass assembly.

• Pull the bottom of the glass frame out and carefully lower

the glass until the two tabs at the top of the glass frame
clear the upper bracket.

Replacing Fixed Glass Assembly

• Place the two tabs at the top of the glass frame into the

location bracket.

• Pivot the bottom in and secure the bottom of the glass

frame with the two latches.

Air Shutter Settings

NG

LP

QVI-35FB-S

Full Open

Full Open

SURROUND LOCATING TABS

FIREBOX