C. junction box installation, D. fan replacement – Quadra-Fire QVI-35FB-S User Manual

Page 26

Advertising
background image

Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08

26

C. Junction Box Installation

Figure 10.3 Junction box installation

JUNCTION

BOX

SIDEWALL

FEED PLUG

THROUGH HOLE

INSERT STRAIN RELIEF

AROUND CORD IN THIS END

FROM OUTSIDE OF UNIT

SCREW

PROVIDED

Optional Accessories

Connecting the electrical junction box is required if using

a blower or remote.

• Plug the cord into a convenient outlet.

• Must use cord supplied.

WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.

D. Fan Replacement

On units already installed removal of decorative front,
surround and gas insert is required.

• Detach fl exible liner from back of unit if insert is in-

stalled.

• Remove the four screws on the cover plate (see Figure

10.4).

Figure 10.4

FAN

COVER

PLATE

POWER

CORD

GROUND

WIRE

• Remove the old fan. See Figure 10.5.

• Place the new fan in between the bend up tabs.

• Install and wire the fan per instruction shipped with the

fan.

• The ground wire of the fan can clip on the side of the

base pan.

• Reinstall the cover plate back on the unit. Make sure the

fan does not make contact with the back wall to prevent
noise from vibration.

Advertising